Project Description

P235GH 1.0345 EN 10216-2 seamless boiler and pressure tube, normalized, bundled
1.0345EN designation
235 MPayield, 0.2%
360 – 500 MPatensile
400 °Ctabulated design range
Normalizeddelivery condition
EN 10216-2product standard
MOQ 1 tonne per size
Lead time 15–25 days
Third party SGS / BV / TUV
Quote within 24 hours
Certificate EN 10204 3.1
Boiler or pressure tube to EN 10216-2? Send OD, wall, design temperature and quantity — P235GH and P265GH differ by 30 MPa of yield and the price is close.
Get a quote

P235GH is the base non-alloy grade of EN 10216-2, the part of the pressure tube standard written for elevated temperature service. It is the European counterpart of ASTM A106 Grade B and the grade that most boiler and pressure equipment in Europe is still designed around: 235 MPa yield, 360–500 MPa tensile, normalized delivery, 27 J impact at 20 °C, and a table of 0.2% proof stress values up to 400 °C. It is not a high-temperature alloy. Above roughly 350 °C the allowable stress falls sharply, and above 400 °C there is no tabulated data at all — that is where 16Mo3 and 13CrMo4-5 take over. The distinction between P235GH and P235TR2 is design basis, not appearance.

What the standard actually guarantees

Table 1 — Scope of EN 10216-2 for P235GH

Item Requirement Practical meaning
Service Elevated temperature pressure purposes Design must use the standard’s proof stress table, not the room-temperature yield
Delivery condition Normalized (N) Air cooled from 900–950 °C; uniform ferrite-pearlite
Tabulated temperature range 20 – 400 °C Above 400 °C there is no design data in the standard
Impact 27 J at 20 °C Not a low-temperature grade; use EN 10216-4 below 0 °C
Certificate EN 10204 3.1 Heat number, chemistry, tensile, impact, heat treatment record

Chemical composition

Table 2 — Chemical requirements, heat analysis (%)

Element Requirement Note
Carbon 0.16 max Lower carbon improves weldability and toughness
Silicon 0.35 max Deoxidation
Manganese 0.40 – 1.20 Strength and deoxidation
Phosphorus 0.025 max Restricted for toughness
Sulphur 0.020 max Restricted for weldability
Aluminium, total 0.020 min Fine grain practice; the difference between GH and TR
Chromium 0.30 max Residual
Copper 0.30 max Residual
Nickel 0.30 max Residual
Molybdenum 0.08 max Residual; above this it becomes a Mo grade
Niobium 0.010 max Residual
Titanium 0.040 max Residual
Vanadium 0.02 max Residual

Mechanical properties

Table 3 — Room-temperature requirements

Property Requirement Note
Yield, 0.2% 235 MPa min Reduces above 16 mm wall
Tensile 360 – 500 MPa The upper limit is enforced
Elongation in 50 mm 25% min —
Impact, Charpy V 27 J at 20 °C Transverse where wall allows
Hardness Not specified Typically 140–165 HBW
Grain size Fine grain, Al-killed Required for the elevated-temperature data to apply

Elevated-temperature design

EN 10216-2 tabulates the 0.2% proof stress for P235GH from 20 to 400 °C. The values fall steadily: by 300 °C the proof stress is roughly three quarters of the room-temperature yield, and by 400 °C roughly two thirds. Above 400 °C the standard is silent, which is the point at which the design has to move to 16Mo3 or 13CrMo4-5 if the temperature cannot be reduced.

Table 4 — Design range and where the next grade starts

Parameter Value
Tabulated proof stress range 20 – 400 °C (EN 10216-2 Table 5)
Typical boiler service Up to 350 °C steam; economiser and lower waterwall
Practical ceiling 400 °C, where the tabulated data ends
Next grade up 16Mo3 to 500 °C, then 13CrMo4-5 to 530 °C
Low-temperature limit 0 °C for the standard impact test; below that EN 10216-4

P235GH against P265GH and A106 B

Table 5 — Grade selection for a pressure tube

P235GH P265GH A106 Gr.B
Standard EN 10216-2 EN 10216-2 ASTM A106
Yield 235 MPa 265 MPa 240 MPa
Tensile 360 – 500 MPa 410 – 530 MPa 415 MPa min
Impact 27 J at 20 °C 27 J at 20 °C Not standard
Elevated data To 400 °C To 400 °C ASME table to 538 °C
Typical use Boiler and vessel, European code Higher pressure at the same wall US code piping and boiler

Sizes and tolerances

Table 6 — Dimensional range

Parameter Range / tolerance
Outside diameter 10.2 – 762 mm
Wall thickness 1.6 – 100 mm
OD tolerance ±0.75% or ±0.5 mm (D2)
Wall tolerance −12.5% / +15% (S2), or ±10% (S1)
Length 5 – 7 m random, or fixed 3 – 12 m
Straightness 0.2% of length
Ends Plain, bevelled, or threaded

Where P235GH is used

Boiler waterwalls

Membrane wall and lower furnace tubes where the metal temperature stays below 400 °C and the pressure is moderate.

Economisers

Feedwater heating banks, where the tube is finned or bare and the duty is below the creep range.

Steam headers

Low-pressure and saturated steam headers, flanged and welded, with normalized tube and a 3.1 certificate.

Pressure vessels

Shell and nozzle tube in small vessels built to EN 13445, where P235GH is the default plate and tube grade.

Heat exchangers

Shell-side and low-temperature tube bundles in process duty without chlorides.

Piping spools

Steam and condensate lines in plant distribution, where A106 B is unavailable and the European grade is specified.

Frequently asked questions

What is the maximum temperature for P235GH?

400 °C, which is where EN 10216-2 stops tabulating proof stress. In practice most boiler designs switch to 16Mo3 above about 400 °C and to 13CrMo4-5 above 480 °C, because the carbon steel wall becomes uneconomical before it becomes unsafe.

Is P235GH the same as P235TR2?

No. P235TR2 is EN 10216-1 for room-temperature service with 27 J at 0 °C; P235GH is EN 10216-2 for elevated temperature, normalized, with 27 J at 20 °C and proof stress data to 400 °C. Same yield, different design basis and different standard.

Can P235GH replace A106 Grade B?

In many European designs, yes, and the reverse is often accepted too. They are close but not identical: P235GH has a guaranteed 235 MPa yield with mandatory impact testing and fine grain practice, while A106 B has 240 MPa and no standard impact requirement. The substitution needs design approval.

Why is aluminium specified as a minimum?

Aluminium addition produces fine grain steel, which is what gives P235GH its toughness and its elevated-temperature proof stress. A heat with aluminium below 0.020% does not meet the standard, and the tube cannot be certified to EN 10216-2 whatever its tensile results.

What is the difference between P235GH and P265GH?

Yield: 235 against 265 MPa, with tensile 360–500 against 410–530 MPa. P265GH is chosen when the design pressure will not close in P235GH at an economic wall. Both are normalized and both are tabulated to 400 °C.

Can P235GH be supplied in the cold drawn condition?

Yes, cold drawn tube is normalized after drawing to meet the delivery condition. Cold drawn plus normalized gives tighter dimensional tolerance than hot finished, at a higher price. State the tolerance class as well as the grade.

Is impact testing at lower temperature available?

Yes, by agreement, but the grade is not designed for it. If the design temperature is below 0 °C, EN 10216-4 grades such as P215NL or P265NL are the correct choice rather than a special P235GH.

What is the minimum order and lead time?

1 tonne per size for standard dimensions. Lead time is 15–25 days; larger diameters and non-standard walls run longer. Third-party inspection adds about a week.

Send the design temperature and the code. P235GH, P265GH and 16Mo3 are chosen by temperature, not by price. The quotation will state the standard, the delivery condition and the test scope.
Request a quote
WhatsApp

Related products

All boiler and pressure tube · Guide: the five parts of EN 10216 and how to read a pressure tube drawing

Also in this range: P235TR2 (1.0255) pressure tube · DIN 17175 boiler pipe · EN 10297-1 E355 mechanical tube · EN 10297-1 E275 mechanical tube.

Request a quotation

Give us OD, wall, length, quantity, design temperature and whether impact testing above the standard 20 °C is required. Tell us the design code if the tube is for a coded vessel.

    Your Name *

    Your Email *

    Company Name

    Phone / WhatsApp *

    Grade & Standard (e.g. ASTM A106 Gr.B, EN 10216-2 P265GH)

    Size, OD × WT (e.g. 88.9 × 5.49 mm)

    Quantity & Unit (e.g. 500 m / 20 t)

    Destination Port

    Drawing or Datasheet (pdf, dwg, step, xlsx; max 5 MB)

    Further Information