Project Description

Lead time 15–25 days
Test category TC1 / TC2
Quote within 24 hours
Impact 40 J at +20 °C
P265GH — EN number 1.0425 — is the non-alloy elevated-temperature pressure tube grade of EN 10216-2, sitting one step above P235GH with a guaranteed minimum yield of 265 MPa across the same temperature envelope. That extra 30 MPa is the whole reason it exists: it lets a designer hold a wall thickness that would otherwise have to grow, on boiler tubes, header stubs, feedwater and steam lines, and pressure vessel nozzles. Two things separate it from ordinary carbon pipe. It is aluminium-killed fine grain steel, so it keeps toughness after normalizing, and it carries mandatory impact testing with elevated-temperature proof strength published to 450 °C. We supply it normalized in test category TC1 or TC2, OD 10 to 610 mm, with the chemical, tensile, impact and high-temperature values on an EN 10204 3.1 certificate.
Why P265GH rather than ordinary carbon steel
EN 10216-2 does not simply rename a carbon steel. The grade requires fully killed steel with a minimum aluminium content of 0.020%, which pins the grain size and keeps the impact transition temperature low after normalizing. It also caps the residual elements collectively — Cr + Cu + Mo + Ni not exceeding 0.70% — because those residuals are what make a heat brittle or unpredictable in elevated-temperature service.
The practical consequence: a P265GH tube can be normalized, impact tested and welded without the fabricator having to qualify a special procedure, and it will still hold its guaranteed proof strength at 300 °C. A commercial carbon tube cannot promise either.
Chemical composition
Table 1 — P265GH / 1.0425 chemistry, cast analysis (%)
| Element | Requirement | Element | Requirement |
|---|---|---|---|
| C | 0.20 max | Al, total | 0.020 min |
| Si | 0.40 max | Cu | 0.30 max |
| Mn | 1.40 max | Nb | 0.010 max |
| P | 0.025 max | Ti | 0.040 max |
| S | 0.020 max | V | 0.02 max |
| Cr | 0.30 max | Cr + Cu + Mo + Ni | 0.70 max |
| Mo | 0.080 max | Ni | 0.30 max |
Aluminium is the line that matters. A heat at 0.015% Al may pass every mechanical test and still fail the specification — and it will behave differently in the heat-affected zone. Ask for the Al value on the certificate, not just the tensile result.
Mechanical properties
Table 2 — Room temperature tensile and yield by wall thickness
| Wall thickness | Yield ReH min | Tensile Rm | Elongation A min (longitudinal / transverse) |
|---|---|---|---|
| Up to 16 mm | 265 MPa | 410 – 570 MPa | 23% / 21% |
| Over 16 – 40 mm | 255 MPa | 410 – 570 MPa | 23% / 21% |
| Over 40 – 60 mm | 245 MPa | 410 – 570 MPa | 23% / 21% |
Table 3 — Impact properties, minimum average absorbed energy
| Test temperature | Longitudinal | Transverse | Note |
|---|---|---|---|
| +20 °C | 40 J | 28 J | The default test for TC1 and TC2 |
| 0 °C | 27 J | — | Quoted when the design temperature is low |
| −10 °C | On request | — | Needs to be specified; not part of the base grade |
Impact values are minimum averages for a set of three specimens, with a single value allowed to fall below the average but not below 70% of it. If your specification calls for a lower test temperature than 0 °C, say so at enquiry — it changes the heat treatment route and the price.
Proof strength at elevated temperature
This is the table the boiler designer actually uses. Note that the guaranteed strength falls roughly 40% between 100 °C and 450 °C, which is why a line sized on room-temperature yield will be under-designed at temperature.
Table 4 — Minimum proof strength Rp0.2 at temperature, wall up to 60 mm
| Temperature | Rp0.2 min | Temperature | Rp0.2 min |
|---|---|---|---|
| 100 °C | 226 MPa | 350 °C | 141 MPa |
| 150 °C | 213 MPa | 400 °C | 134 MPa |
| 200 °C | 192 MPa | 450 °C | 128 MPa |
| 250 °C | 171 MPa | 500 °C | Not specified |
| 300 °C | 154 MPa | 550 °C | Not specified |
The table stops at 450 °C because that is where the standard stops. Above 450 °C the design needs a creep-resisting grade — 16Mo3 or 13CrMo4-5 — not a thicker carbon wall.
Heat treatment
Table 5 — Normalizing conditions
| Condition | Austenitizing temperature | Cooling | Tempering |
|---|---|---|---|
| +N (normalized) | 880 – 940 °C | Air | None |
| +N with normalizing forming | 880 – 940 °C | Air | None — permitted by the standard |
Normalizing forming means the final forming operation is done at normalizing temperature and the part is then allowed to cool in air, so no separate reheat is needed. It is common for header stubs and bends and has to be declared on the order.
Standards and equivalents
Table 6 — P265GH against the specifications it is compared with
| System | Designation | Product form | Difference |
|---|---|---|---|
| EN | EN 10216-2 — P265GH / 1.0425 | Seamless pressure tube | Reference specification for this page |
| EN | EN 10217-2 — P265GH | Welded pressure tube | Electric welded version; same grade name, different product |
| ASTM | A106 Grade B | Seamless pipe | Closest US equivalent. 240 MPa yield against 265 MPa — not interchangeable without review |
| ASTM | A516 Grade 70 | Plate | Same strength class for vessel shells and tube sheets |
| JIS | JIS G3456 STPT410 | High temperature pipe | Japanese equivalent grade |
| GB | GB 5310 20G / GB/T 3087 20# | Boiler tube / low pressure pipe | 20G is the closer match; 20# has no elevated temperature data |
| DIN | DIN 17175 St45.8 | Seamless tube | Withdrawn, superseded by EN 10216-2 |
The most common substitution request we see is A106 B in place of P265GH. It usually passes on tensile and fails on yield — 240 against 265 MPa — and it has no aluminium requirement. For a European pressure vessel that is normally enough to stop the substitution.
Inspection and test category
Table 7 — What is tested, and what TC2 adds
| Test | TC1 | TC2 | Notes |
|---|---|---|---|
| Cast analysis | Required | Required | On the certificate either way |
| Tensile at room temperature | Required | Required | Yield, tensile, elongation |
| Impact test | Required | Required | +20 °C as standard |
| Flattening / ring test | Required | Required | Per size and wall |
| Leak tightness (hydrostatic) | Required | Required | Or NDT by agreement |
| Dimensional and visual | Required | Required | — |
| Product analysis | Optional | Required | Confirms the finished tube, not just the cast |
| NDT of the tube body | Not required | Required | Eddy current or ultrasonic |
| Elevated temperature tensile | Optional | Optional | Ordered when the design needs verified data |
Where P265GH is the right answer
Boiler waterwall and economiser
Furnace wall tubes and economiser sections where the metal temperature stays under 400 °C and carbon steel creep is not yet the governing case.
Header stubs and nozzles
Short thick-wall connections into drums and headers. The 265 MPa yield holds the wall down where a P235GH design would grow.
Feedwater and steam lines
Low and medium pressure steam and feedwater piping in combined heat and power and industrial boiler plants.
Pressure vessel shells
Shell courses and end closures where EN 10028-2 P265GH plate is used and the tube specification has to match the plate.
Heat exchanger shells
Shell-side service in the 200–400 °C band, particularly where a notified body requires documented elevated temperature data.
Air receiver and accumulator
Compressed air and nitrogen vessels built to the pressure equipment directive, where TC2 and a 3.1 certificate are the default expectation.
Frequently asked questions
What is the difference between P265GH and P235GH?
Thirty megapascals of guaranteed yield — 265 against 235 — and the same temperature envelope up to 450 °C. The choice is purely a wall thickness question: if the P235GH design needs a wall the fabricator considers excessive, P265GH closes it without changing anything else on the line.
Can A106 Grade B replace P265GH?
Rarely without a review. A106 B guarantees 240 MPa yield against 265 MPa, has no aluminium-killed fine grain requirement and no mandatory impact test. On a European pressure vessel that combination usually fails the design check at the first review.
What does test category TC1 and TC2 mean in practice?
TC2 adds NDT of the tube body and a product analysis on the finished tube. For boiler and pressure equipment in Europe, TC2 is the normal order; TC1 appears on less critical or non-notified work. If the enquiry does not state a category, we will ask before quoting.
At what temperature does P265GH stop being suitable?
The standard publishes proof strength to 450 °C, and that is the practical ceiling. Above it the design has to consider creep, which means 16Mo3 or 13CrMo4-5 rather than more carbon steel.
Is P265GH the same as P265GH to EN 10217-2?
The grade is the same, the product is not. EN 10216-2 is seamless, EN 10217-2 is electric welded. They are separate specifications with separate test schedules and cannot be certified as each other.
Is it always normalized?
Normalizing is the standard delivery condition, and normalizing forming is permitted. As-rolled supply exists in the market but should be treated with suspicion unless the mill can show the mechanical properties and impact results for the actual condition supplied.
What certificate and marking do you supply?
EN 10204 3.1 with heat number, cast and product analysis, tensile, yield, elongation, impact energy and the test temperature. Marking is stencilled or stamped on each length with grade, size, heat number and the manufacturer’s mark, and repeated on the bundle tag.
What is the minimum order and lead time?
One tonne per size. Lead time 15–25 days; TC2 with third-party inspection adds about a week, and diameters above 400 mm run longer because fewer mills roll them.
Request a quote
Related products
P355NH (1.0565) TubeNormalized, 355 MPa yield
16Mo3 (1.5415) Tube0.3% Mo for service to 500 °C
13CrMo4-5 (1.7335) Tube1.25Cr-0.5Mo for superheater service
ASTM A106 Seamless PipeThe US carbon steel equivalent, Gr A / B / C
EN 10216-2 Pressure TubeThe full grade range on one page
All boiler and pressure tube — carbon, alloy and stainless · Guide: which standard governs your order
Request a quotation
Tell us OD, wall, quantity, design temperature and the test category you need. We reply within 24 hours with price, lead time and certificate scope — and we will query an impact temperature that the grade cannot meet before you order.