405 is the 12% chromium ferritic stainless steel that does not harden when it is welded. That single property is why it exists. Standard 410 hardens in the heat-affected zone, needs preheat and post-weld heat treatment, and cracks if either is skipped; 405 keeps the carbon at 0.08% maximum and adds 0.10–0.30% aluminium, which suppresses austenite formation enough that the weld zone stays soft and ductile. The trade is strength and hardenability: 405 cannot be quenched and tempered, so it is used annealed, at about 415 MPa tensile, in heat exchanger tubes, vessel internals, trays, ducting and catalytic cracker parts where a 12% chromium steel has to be fabricated on site and then put into service without a heat treatment furnace.
The three 12% chromium grades, side by side
Table 1 — 405 against 410 and 430 — pick by fabrication route, not by corrosion
| 405 | 410 | 430 | |
|---|---|---|---|
| UNS | S40500 | S41000 | S43000 |
| EN / W.-Nr. | 1.4002 / X6CrAl13 | 1.4006 / X12Cr13 | 1.4016 / X6Cr17 |
| Chromium | 11.5 – 14.5% | 11.5 – 13.5% | 16.0 – 18.0% |
| Carbon | 0.08 max | 0.15 max | 0.12 max |
| Aluminium | 0.10 – 0.30% | — | — |
| Hardenable | No | Yes, to 42 HRC | No |
| Weld without PWHT | Yes — the design intent | No | Yes, in thin sections |
| Corrosion level | Similar to 410 | Similar to 405 | Better; 17% Cr |
Chemical composition
Table 2 — Chemical requirements, heat analysis (%)
| Element | ASTM A268 / A511 | EN 10088-2 / 1.4002 |
|---|---|---|
| Carbon | 0.08 max | 0.08 max |
| Manganese | 1.00 max | 1.00 max |
| Silicon | 1.00 max | 1.00 max |
| Phosphorus | 0.040 max | 0.040 max |
| Sulphur | 0.030 max | 0.030 max |
| Chromium | 11.5 – 14.5 | 12.0 – 14.0 |
| Aluminium | 0.10 – 0.30 | 0.10 – 0.30 |
| Nickel | 0.50 max | — |
The aluminium range is not a residual — it is the alloying element that makes the grade work. A heat with aluminium below 0.10% will harden in the weld zone like 410, and one above 0.30% becomes difficult to draw and weld cleanly. Check the aluminium on the certificate, not just the chromium.
Mechanical properties
Table 3 — Annealed properties, room temperature
| Property | Requirement | Typical as supplied |
|---|---|---|
| Tensile strength | 415 MPa min | 450 – 520 MPa |
| Yield strength, 0.2% | 170 MPa min | 210 – 280 MPa |
| Elongation in 50 mm | 20% min | 25 – 32% |
| Hardness | ≤ 179 HBW | 150 – 170 HBW |
| Modulus of elasticity | 200 GPa | — |
| Impact, Charpy V | Not specified as standard | 27 J at 20 °C on request |
Corrosion and high-temperature behaviour
405 sits at the same corrosion level as 410: good in atmosphere, fresh water, steam, and many organic and petroleum products; poor in chlorides, seawater and dilute sulphuric acid. The aluminium addition gives it one advantage over 410 — better resistance to oxidation and to sulphidation at elevated temperature, which is why it appears in refinery heater and cracker service where the metal temperature reaches 600–800 °C and the environment is sulphur-bearing.
Table 4 — Service limits
| Environment | 405 performance | Note |
|---|---|---|
| Atmosphere, fresh water, steam | Good | Light staining in coastal atmosphere |
| Chlorides and seawater | Not suitable | PREN about 12; pitting and SCC risk |
| Oxidising sulphidation, 600–800 °C | Better than 410 | The aluminium effect; used in refinery internals |
| Scaling in air | Good to about 700 °C continuous | Above that, 430 or 446 is the better choice |
| Dilute sulphuric acid | Attacked | Use 904L or Alloy 20 |
| Caustic soda | Acceptable to moderate concentration | SCC risk at high concentration and temperature |
Welding: the reason to buy 405
Table 5 — Welding parameters
| Parameter | Recommendation | Why |
|---|---|---|
| Preheat | 100–200 °C, optional | Not required for cracking; helps moisture removal and bead shape |
| Filler | ER430 or ER309L | Matching ferritic filler gives a soft weld; 309L gives better toughness at the joint |
| Post-weld heat treatment | Not required | The low carbon and aluminium keep the HAZ from hardening |
| Interpass temperature | ≤ 300 °C | Limits grain growth and sigma formation in thick sections |
| Shielding gas | Argon, or argon + 2% oxygen for TIG | Standard austenitic practice applies |
405 welds without PWHT, but it is still a ferritic steel: the weld zone grain coarsens and toughness drops. For a vessel in low-temperature service, impact testing of the procedure qualification is still required even though the base metal does not harden.
Dimensions and tolerances
Table 6 — Tube and pipe range
| Form | Range | Tolerance | Standard |
|---|---|---|---|
| Seamless tube, cold drawn | OD 6 – 114 mm, WT 0.8 – 12 mm | OD ±0.10 mm, WT ±10% | ASTM A268, A511 |
| Seamless pipe | NPS 1/2 – 8, SCH 10 – 160 | Per A999 | ASTM A268 |
| Welded tube | OD 12 – 219 mm, WT 0.8 – 6 mm | OD ±0.15 mm | ASTM A268 |
| Length | 1 – 7 m fixed | ±3 mm under 3 m, ±5 mm above | — |
| Surface | Pickled, bright annealed, or ground | Ra ≤ 1.6 µm pickled | — |
Standards and equivalents
Table 7 — Cross reference
| System | Designation | Scope |
|---|---|---|
| ASTM | A268 TP405 / A511 TP405 | Seamless and welded ferritic tube |
| ASTM | A240 S40500 | Plate and sheet, not tube |
| EN | 1.4002 / X6CrAl13 | EN 10088-2 sheet, EN 10216-5 tube on request |
| JIS | SUS405 (G3463 / G4304) | Tube and plate |
| GB | 0Cr13Al | The Chinese equivalent |
Where 405 is the right answer
Heat exchanger tube
Mild process water and oil coolers where the tube is rolled into a carbon steel tubesheet and welded, and PWHT of the assembly is impossible.
Vessel internals
Trays, baffles and supports inside carbon steel vessels, welded on site without a furnace.
Refinery heater parts
Tube supports and hangers in sulphur-bearing service at 600–800 °C, where the aluminium gives an edge over 410.
Catalytic cracker internals
Cyclone parts and liners where erosion resistance and weldability both matter and 410 would need heat treatment.
Ducting and flues
Thin-wall welded duct for flue gas, where the assembly is too large to heat treat and 304 is not justified.
Automotive exhaust
Hangers, flanges and heat shields where 409L is not available and 430 is over-specified on formability.
Frequently asked questions
Why does 405 not harden when welded?
Two reasons: carbon is capped at 0.08%, and 0.10–0.30% aluminium stabilises ferrite so the heat-affected zone does not transform to martensite on cooling. Without the aluminium, a 0.08% carbon 12% Cr steel would still harden slightly in thick sections.
Can 405 be heat treated to increase strength?
No. It is ferritic and not hardenable by quenching. If the part needs 600 MPa or more, use 410 quenched and tempered, or move to a duplex grade. 405 is supplied annealed and stays around 415–520 MPa tensile.
What filler should be used to weld 405?
ER430 or E430 for a matching joint, or ER309L where the joint needs more toughness and the service is not at high temperature. Do not use 308L for high-temperature service — the nickel-rich weld has different thermal expansion and will crack under cycling.
Is 405 the same as 410S?
No, though both are low-carbon 12% Cr. 410S has no aluminium addition and is a low-carbon version of 410; 405 has 0.10–0.30% aluminium specifically to prevent hardening in the weld zone. For welded assemblies 405 is the more forgiving grade.
What is the maximum service temperature for 405?
About 700 °C continuous in air for scaling resistance, and 600–800 °C in sulphidising refinery service where the aluminium oxide layer is protective. Above 800 °C the scale becomes unstable and 446 or a nickel alloy is the correct choice.
Can 405 be used in seawater?
No. At 12% chromium the pitting resistance is far below what chlorides demand, and the ferritic structure is susceptible to stress corrosion cracking in hot chloride service. Use 2205 or a super duplex.
Is 405 magnetic?
Yes, strongly magnetic, like all ferritic grades. It is often chosen for that reason in solenoid and sensor components.
What is the minimum order and lead time?
500 kg per size for standard dimensions. Lead time is 15–25 days depending on size and surface finish; pickled and annealed stock is faster than ground tube. Third-party inspection adds about a week.
Request a quote
Related products
10Cr17 / 430 Tube17% Cr ferritic for exhaust and appliances
444 (1.4521) Tube2% Mo ferritic with chloride resistance
SUH409L (1.4512) TubeTi-stabilised 11% Cr for exhaust
ASTM A268 Ferritic TubeThe general ferritic tube specification
ASTM A312 TP304When chlorides rule out the ferritic grades
All stainless steel tube · Guide: ferritic stainless steels, and why they are not just cheaper 304
Also in this range: 444 (1.4521) ferritic tube · 10Cr17 / 430 ferritic tube · SUH409L (1.4512) exhaust tube · 410 / 410L / 410S martensitic tube.
Request a quotation