Project Description

F55 S32760 1.4501 super duplex stainless steel pipe and tube for seawater and sour service
1.4501 / S32760EN and UNS
550 MPayield, 0.2%
PREN ≥ 40pitting resistance
3.0 – 4.0%molybdenum
0.5 – 1.0%tungsten
NACE MR0175sour service listed
MOQ 500 kg per size
Lead time 25–35 days
Third party SGS / BV / TUV
Quote within 24 hours
Testing ferrite count + corrosion test
Specifying F55 for seawater or sour service? Send the chloride level, H2S partial pressure and temperature — the acceptable hardness and ferrite content depend on all three.
Get a quote

F55 — S32760 in UNS, 1.4501 in EN — is a 25% chromium super duplex with molybdenum, nitrogen, copper and tungsten, and a pitting resistance equivalent above 40. That number is what puts it into seawater cooling systems, subsea flowlines, riser joints and chemical tanker piping, where 2205 pits and the super austenitic grades do not have the strength. The tungsten and copper are what separate it from 2507: both are 25Cr super duplexes, but F55 is the grade written into NORSOK and many subsea specifications, and its composition is balanced for weld toughness in thick sections. It is a difficult alloy to weld and it cannot be heat treated after welding, so the procedure qualification is part of the product, not an afterthought.

Chemistry

Table 1 — Chemical composition, EN 10088-2 / ASTM A240 (%, limits)

Element 1.4501 / S32760 Function
Carbon 0.03 max Prevents carbide precipitation during welding
Chromium 24.0 – 26.0 Passive film and pitting resistance
Nickel 6.0 – 8.0 Balances the ferrite-austenite ratio at about 50/50
Molybdenum 3.0 – 4.0 Pitting and crevice corrosion resistance
Nitrogen 0.20 – 0.30 Strength and pitting resistance; also stabilises austenite
Copper 0.50 – 1.00 Resistance to reducing acids
Tungsten 0.50 – 1.00 Additional pitting resistance; the F55 signature
Manganese 1.0 max Residual
Silicon 0.8 max Deoxidation

Mechanical properties

Table 2 — Room-temperature requirements

Property Requirement Note
Yield, 0.2% 550 MPa min Over three times 316L
Tensile 750 MPa min —
Elongation in 50 mm 25% min —
Hardness ≤ 32 HRC typical acceptance Hardness is the practical check on phase balance
Impact at −46 °C 45 J typical Subsea specifications often require 45 J at −46 °C
Ferrite content 35 – 55% Measured by metallography; outside this band, toughness or corrosion suffers

Corrosion performance

Table 3 — Where F55 is specified and where it is not enough

Duty F55 performance Comment
Seawater, flowing Good to 60 °C Standard for seawater cooling and firewater systems
Seawater, stagnant or chlorinated Marginal above 40 °C Crevice corrosion under deposits is the failure mode
Chloride SCC Resistant to about 100 °C The reason it replaces 316L in hot chloride service
Sour service (H2S) Listed in NACE MR0175 Limits depend on partial pressure and temperature
Sulphuric acid Moderate 904L or 6Mo better in concentrated acid
Erosion corrosion Excellent Higher hardness and yield than austenitic grades

F55 against 2507 and 2205

Table 4 — Super duplex grade selection

2205 (S32205) F55 (S32760) 2507 (S32750)
Chromium 22.0 – 23.0 24.0 – 26.0 24.0 – 26.0
Molybdenum 3.0 – 3.5 3.0 – 4.0 3.0 – 5.0
Nitrogen 0.14 – 0.20 0.20 – 0.30 0.24 – 0.32
Tungsten — 0.50 – 1.00 —
PREN ≈ 35 ≥ 40 ≥ 42
Yield 450 MPa 550 MPa 550 MPa
Typical use Moderate chloride, process plant Seawater, subsea, sour service Seawater, higher temperature

Sizes and forms

Table 5 — Product range

Form Range Tolerance
Seamless tube OD 6 – 219 mm, WT 1 – 20 mm OD ±0.15 mm, WT ±10%
Welded tube OD 12 – 508 mm, WT 0.8 – 10 mm OD ±0.20 mm
Pipe NPS 1/2 – 24, SCH 10 – 160 Per A999 / EN 10216-5
Length 3 – 12 m +20 / 0 mm
Surface Pickled and passivated Ra ≤ 1.6 µm
Testing Ferrite count, hardness, corrosion test ASTM A923 Method A/B/C on request

Welding: where super duplex fails

Table 6 — Welding parameters

Parameter Recommendation
Filler ER2594 (25Cr super duplex) or ER2595 for higher alloy
Heat input 0.5 – 1.5 kJ/mm, narrow band
Interpass ≤ 150 °C, measured not guessed
Preheat / PWHT None; PWHT prohibited
Root shielding Argon with 2–3% nitrogen; nitrogen loss promotes ferrite
Post-weld Pickle and passivate; brush only is not acceptable
Qualification Impact at −46 °C, ferrite count, ASTM A923 corrosion test

The common failure in F55 fabrication is not the weld metal — it is the heat-affected zone. Too much heat input coarsens the ferrite and drops toughness; too little leaves untempered ferrite and drops corrosion resistance. Both show up in the A923 test, which is why subsea specifications require it rather than accepting a hardness reading alone.

Where F55 is the right answer

Subsea flowlines

Line pipe and jumpers in chlorinated seawater and sour production, where 2205 does not meet the corrosion allowance.

Seawater cooling

Heat exchanger tube and pipework on offshore platforms and FPSOs, the largest single use of the grade.

Firewater systems

Deluge and firewater ring mains where stagnant seawater sits in the line for long periods.

Chemical tankers

Cargo piping and tank heating coils for aggressive chemicals, where the copper addition helps in reducing acids.

Desalination

Brine heater and high-pressure seawater sections, where 2205 pits and 6Mo is not strong enough.

Sour wells

Tubing and surface lines to NACE MR0175, with hardness and ferrite control on every heat.

Frequently asked questions

What is the difference between F55 and 2507?

Both are 25% chromium super duplex with PREN above 40. F55 (S32760 / 1.4501) contains 0.5–1.0% tungsten and 0.5–1.0% copper and is written into NORSOK and many subsea specifications. 2507 (S32750 / 1.4410) has no tungsten, a slightly higher nitrogen range and a PREN of 42 or more. They are not interchangeable without a design review.

Is F55 suitable for seawater?

Yes, in flowing seawater up to about 60 °C, which is why it is the default for offshore cooling and firewater. In stagnant or chlorinated seawater above 40 °C, crevice corrosion under deposits is the limiting mechanism and a higher-alloy grade or a corrosion allowance is needed.

Can F55 be used in sour service?

It is listed in NACE MR0175 / ISO 15156, subject to limits on H2S partial pressure, temperature, pH and chloride content, plus hardness control. State the full sour condition at enquiry — the standard’s acceptance table cannot be applied from the grade name alone.

What ferrite content should the tube have?

35–55%, measured metallographically. Below 35% the corrosion resistance and strength fall; above 55% the toughness and weldability suffer. The mill certificate should state the measured value, not just “balanced”.

Can F55 be heat treated after welding?

No. Solution annealing requires about 1,100 °C and a water quench, which cannot be done on a fabricated spool. PWHT in the 300–900 °C range forms sigma phase and destroys both toughness and corrosion resistance.

What test is required on the weld?

ASTM A923 is the standard: Method A for intermetallic phase, Method B for toughness, Method C for corrosion. Subsea specifications normally require all three plus impact testing at −46 °C and a ferrite count.

Why is F55 more expensive than 2205?

More chromium, molybdenum, nitrogen, tungsten and copper, a narrower process window, and lower mill yield. The premium is roughly 30–50% per tonne, which is usually justified by the corrosion allowance it removes rather than by the strength.

What is the minimum order and lead time?

500 kg per size for seamless tube, 1 tonne for pipe. Lead time is 25–35 days; A923 testing and third-party witness add about a week. Thick-wall and large-diameter sizes run longer.

Send the service condition, not just the grade. Chloride level, H2S partial pressure, temperature and design code decide whether F55, 2507 or 6Mo is correct. The quotation will state the ferrite and hardness acceptance.
Request a quote
WhatsApp

Related products

All stainless steel tube · Guide: duplex and super duplex — PREN, phase balance and welding

Also in this range: 2101LDX (1.4162) lean duplex · 2304 (1.4362) lean duplex · 904L (1.4539) stainless pipe · ASTM A312 TP304 pipe.

Request a quotation

Give us the form, size, wall, quantity, service temperature, chloride level and H2S partial pressure. Tell us whether ASTM A923 and impact testing are required — they change both price and lead time.

    Your Name *

    Your Email *

    Company Name

    Phone / WhatsApp *

    Grade & Standard (e.g. ASTM A106 Gr.B, EN 10216-2 P265GH)

    Size, OD × WT (e.g. 88.9 × 5.49 mm)

    Quantity & Unit (e.g. 500 m / 20 t)

    Destination Port

    Drawing or Datasheet (pdf, dwg, step, xlsx; max 5 MB)

    Further Information