Project Description

Optimized Internal Ribbed Boiler Tubes — Hunan Fushun Metal

Optimized Internal Ribbed Boiler Tubes

Product Description

Internal ribbed tubes are widely used in the water-cooled walls of boilers in power plants. They are primary heat exchange components where spiral protrusions on the inner wall of the tube cause the water inside to rotate, disrupting the film effect during heat transfer and achieving nucleate boiling. These tubes come in two types: standard internal ribbed tubes and optimized internal ribbed tubes.

Standard internal ribbed tubes come in A and B types with a helical angle of 30°, which increases heat transfer efficiency by about 30% compared to ordinary round tubes. Optimized internal ribbed tubes represent the next generation developed from traditional internal ribbed tubes, featuring a helical angle exceeding 40°. Compared to standard internal ribbed tubes, they further enhance heat transfer efficiency by an additional 20%, thus offering superior heat transfer performance. Below is a comparison of the heat transfer characteristics of smooth tubes, standard internal ribbed tubes, and optimized internal ribbed tubes.

Comparison of Parameters for Some T12 Optimized Internal Ribbed Tubes Produced by Company vs Foreign Data

Manufacturer Outer Diameter (mm) Wall Thickness (mm) Number of Threads Thread Height (mm) Thread Top Width (mm) Helical Angle (°) Thread Side Angle (°)
Benteler 35*6.5 34.92 20.55 6 1.26 5.81 42

Company

31.8*5.5 31.75 20.15 6 1.25 5.91 42

Company

34.9*6.1 34.96 21.40 6 1.31 6.04 44

Current Grades of Steel Produced

20G, SA210C, SA210A1, 15CrMoG, 12Cr1MoVG, T2, T12, T23, T91

Standards Implemented (Partial List):

  • GB5310-2008, GB/T 20409-2006: Seamless steel tubes for high-pressure boilers with internal ribs
  • ASME SA-210M-2015
  • ASME SA-213M-2015

Specification Range:

  • Outer Diameter: Φ22mm ~ Φ82.6mm
  • Wall Thickness: 4.0mm ~ 16.0mm

Optimized ribbed tube data

The optimized profile exists for the part of the furnace where standard ribs are not enough — high heat flux combined with low mass flux, where a standard rib can still allow film boiling. The higher rib promotes swirl earlier and keeps the water against the wall.

Standard GB/T 20409-2006; GB 5310-2008; ASME SA-210M; ASME SA-213M
Type Optimized (high-efficiency) internal rib, in addition to Type A and Type B
Difference from standard rib Higher rib and adjusted lead, giving a larger internal surface and earlier transition to nucleate boiling at low mass flux
Grades 20G, SA210A1, SA210C, 15CrMoG, 12Cr1MoVG, T2, T12, T23, T91
Outside diameter 22 mm – 82.6 mm
Wall thickness 4.0 mm – 16.0 mm
Delivery condition Normalized or as-rolled by grade
Testing Hydrostatic, eddy current; rib geometry checked on a sectioned sample
Certificate EN 10204 3.1

Because rib geometry is rolled to a drawing, an optimized tube is not interchangeable with a standard one at the same OD and wall. Send the drawing or the OEM part number if the tube is a replacement for an existing unit.